Variable, low current power supplies are inexpensive and available:
Steps:
1. Verify cell voltages using internal app, record these and any errors if still present.
2. Hook up to DC variable voltage and apply very low charge voltage 3.3VPC (13.2V)
3. Come back in 10 mins to see result.
a) check DC current with clamp meter or other more granular device.
or
b) check app to see if BMS is balancing
4. Based on results, increase voltage to 3.4VPC (13.6V)
5. Leave for 1-2 hr, see result;
a) check DC current with clamp meter or other more granular device
or
b) check app to see if BMS is balancing
6. Based on results, increase voltage to 3.5VPC (14.0V)
7. Leave forever, see result;
a) check DC current with clamp meter or other more granular device
or
b) check app to see if BMS is balancing
Was this article helpful?
That’s Great!
Thank you for your feedback
Sorry! We couldn't be helpful
Thank you for your feedback
Feedback sent
We appreciate your effort and will try to fix the article